Hot Water Circulation Pump for Water Heater
Product Details
As a dedicated Heat Pump Water Pump, the CRP060A circulates heat-transfer fluid between the evaporator and storage tank, preserving the COP advantage of heat pump water heaters. Its 80°C maximum medium temperature aligns with residential heat pump operating ranges (49°C–60°C tank temperature). DOE Building America field data confirms demand-controlled BLDC recirculation reduces hot water energy use by up to 30% versus constant-pumping systems. For solar thermal or glycol-loop applications, the product line offers compatible models covering radiant floor heating and closed-loop hydronic systems.
Installation & Maintenance
● Dedicated Return Line (New Construction): Third pipe from farthest fixture to heater; pump installed on supply side for maximum efficiency.
● Thermostatic Bypass Valve (Retrofit): Valve under farthest sink connects hot/cold lines; pump activates when temperature drops below setpoint.
● Inlet Screen Inspection (Every 6 Months): Check for debris to prevent flow restriction.
● Seal Integrity Check (Annually): Verify all threaded connections remain watertight.
● Impeller Inspection (Annually): Flush housing with descaling solution if flow drops >15% below 20 L/min specification.
Specification
The CRP060A Hot Water Boost Pump delivers 20 L/min at 48W, operates below 45 dB, handles media up to 80°C, and achieves a 200,000-cycle lifespan—ideal for residential recirculation, radiant floor heating, and solar preheat loops.
Specification
|
MODEL:CRP060A |
|||
|
AMBIENT TEMP |
-25~60℃ |
|
|
HUMIDITY |
30-85%RH |
||
|
MEDIUM |
PURE WATER/ANTIFREEZE |
||
|
MEDIUM TEMP |
0~80℃ |
||
|
WATERPROOF |
IPX4 |
||
|
CONSTANT/CONTINUOUS PRESSURE |
3.5MPa/1.5MPa |
||
|
SPECIFICATION |
FEATURE |
||
|
RATED VOLTAGE |
36V DC |
COLOR |
BLACK |
|
RATED CURRENT |
1.33(1±10%)A |
WEIGHT |
250 g |
|
RATED POWER |
48(1±10%)W |
NOISE |
≦ 45dB@1m |
|
MAX FLOW |
20±1L/min |
LIFETIME |
≧200,000 cycles |
|
MAX HEAD |
11±1m |
INSULATION |
E(155℃) |
Frequently Asked Questions
What voltage does this hot water circulation pump require?
The CRP060A requires 36V DC with 48W power consumption. An external AC-to-DC adapter is necessary for mains-powered installations.
Can the CRP060A handle antifreeze in solar thermal loops?
Yes. The pump supports pure water and antifreeze mixtures within the 0–80°C medium temperature range, compatible with glycol-based solar thermal circuits.
How quiet is the CRP060A during operation?
The CRP060A operates at ≤45 dB at 1 meter—a 10–20 dB reduction compared to conventional AC circulation pumps.
What is the expected lifespan?
The CRP060A is rated for ≥200,000 operating cycles. The brushless DC motor eliminates mechanical brush wear, the primary failure point in traditional designs.